Jagadeesan, V and Venkat, Subramaniam (2021) Development of an Automated Nebulizer Spray Pyrolysis System and Its Application in the P-N junction Diode Fabrication. Journal of Physics: Conference Series. pp. 1-11.
Jagadeesan_2021_J._Phys.__Conf._Ser._1921_012009.pdf - Published Version
Download (1MB)
Abstract
An automated nebulizer spray pyrolysis (ANSP) system is developed for fabricating
p-Zn:CuO/n-Si junction diode. The mechanical carriage for the X-Y movement and the
proposed ANSP system is designed using the SolidWorks design software tool. ATmega-328
microcontroller-based control system was developed to control and move the spray nozzle in
the X and Y-axis direction. Zn:CuO (p-type) precursor solution is sprayed on the silicon wafer
(n-type) using this ANSP system to form p-Zn:CuO/n-Si junction diode. The process
parameters and operating conditions were optimized. The fabricated p-Zn:CuO/n-Si junction
diode parameters such as ideality factor (η) and barrier height (ɸb) were studied under dark and
light conditions using Keithley electrometer. The investigation results revealed that the
junction diode has the lowest ideality factor and barrier height
Item Type: | Article |
---|---|
Uncontrolled Keywords: | Nebulizer; spray pyrolysis; microcontroller; diode; ideality factor; barrier height |
Divisions: | PSG College of Arts and Science > Department of Electronics |
Depositing User: | Mr Team Mosys |
Date Deposited: | 23 Jun 2022 03:17 |
Last Modified: | 23 Jun 2022 03:17 |
URI: | http://ir.psgcas.ac.in/id/eprint/1254 |